ELN - Analytical Technique

Chromatography

Purpose

Column chromatography is a technique applied to an experiment to purify compounds according

to their polar magnitude. To achieve successful column chromatography it is important to avoid

contamination.

Notes

- Ensure the there is liquid in the column at all times

- Do not allow the liquid to reach below the silica gel line, continue to refill

- Do not lose any of the liquid product dripping out

Protocol

Conditioning of the column

● Fill the top of the mini-column with 10%-90% ethyl acetate/hexane solvent.

● Obtain a pipet bulb and apply it to the top of the column, squeeze the bulb to force

solvent through the gel portion of the column

● When removing the pipet, maintain pressure and pull the bulb off to avoid inverse

pressure flow

● Do not allow the solvent level to drop below the silica line at the top

Was this document helpful?

ELN - Chromatography

Course: (CHEM 2323, 2423) Organic Chemistry I (CHEM 227)

246 Documents
Students shared 246 documents in this course
Was this document helpful?
ELN - Analytical Technique
Chromatography
Purpose
Column chromatography is a technique applied to an experiment to purify compounds according
to their polar magnitude. To achieve successful column chromatography it is important to avoid
contamination.
Notes
- Ensure the there is liquid in the column at all times
- Do not allow the liquid to reach below the silica gel line, continue to refill
- Do not lose any of the liquid product dripping out
Protocol
Conditioning of the column
Fill the top of the mini-column with 10%-90% ethyl acetate/hexane solvent.
Obtain a pipet bulb and apply it to the top of the column, squeeze the bulb to force
solvent through the gel portion of the column
When removing the pipet, maintain pressure and pull the bulb off to avoid inverse
pressure flow
Do not allow the solvent level to drop below the silica line at the top