No. Questions Marks CLO Complexity
Level
1. Draw the vector diagram of transformer for a resistive load? 02 1 C1
2.
A 100 KVA distribution transformer has full load efficiency of
96% and iron loss is 2 KW. Calculate the all day efficiency of
unity power factor with following loading?
(a)
1
4
full load for 8 hours.
(b)
1
2
full load for 6 hours.
(c) full load for 3 hours.
(d) No load for 7 hours.
04 1 C3